RW-BA PE-ALT-CLT 1X2/1,60 SW
RW-BA PE-ALT-CLT 1X2/1,60 SW
Balise cable for ERTMS/ETCS railway networks
- Nexans ref. : 10205675
Description
Description
Standards
- 
                                            TestIEC 60754-1; IEC 60754-2
Preferential use
 
- EuroBalise cable for ERTMS/ETCS railway networks
- Siemens Approved
Key-points
- Railway networks
- Siemens Approved
- Low reduction factor
- Armoured
Cable construction
- Conductor: Copper wire, 1,6 mm nominal diameter
- Insulation: Solid high density polyethylene
- Stranding: Conductors will be stranded with dielectric fillers in order to get a circular core shape
- Core covering: Plastic tape (s) with overlapping
- Inner sheath: Low density polyethylene
- Screen: Aluminium/polyethylene coated tape longitudinally applied and overlapped
- Intermediate sheath: Low density polyethylene
- Armour: Two galvanized steel tapes
- Outer sheath: Low density polyethylene
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Armour type
                                                            
                                                            
                                                                Galvanized steel tapes 
                                                            
                                                        
                                                                Conductor material
                                                            
                                                            
                                                                Bare copper 
                                                            
                                                        
                                                                Halogen free
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Inner sheath
                                                            
                                                            
                                                                Polyethylene 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                Solid polyethylene 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                PE 
                                                            
                                                        
                                                                Protection
                                                            
                                                            
                                                                - 
                                                            
                                                        
                                                                Screen
                                                            
                                                            
                                                                Aluminium coated tape 
                                                            
                                                        
                                                                Sheath colour
                                                            
                                                            
                                                                Black 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Conductor diameter
                                                            
                                                            
                                                                1.6 mm
                                                            
                                                        
                                                                Nominal outer diameter
                                                            
                                                            
                                                                17.5 mm
                                                            
                                                        
                                                                Precision of diameter
                                                            
                                                            
                                                                +/- 0.7 mm 
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                285 kg/km
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Dielectric strength core to core DC, min.
                                                            
                                                            
                                                                2.5 kV
                                                            
                                                        
                                                                Dielectric strength core to screen DC, min.
                                                            
                                                            
                                                                2.5 kV
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Weather resistance
                                                            
                                                            
                                                                Good 
                                                            
                                                        
                                                                Water proof
                                                            
                                                            
                                                                Radial 
                                                            
                                                        
                                                                Minimum operating temperature
                                                            
                                                            
                                                                -30 °C
                                                            
                                                        
                                                                Maximum operating temperature
                                                            
                                                            
                                                                70 °C
                                                            
                                                        
                                                                Minimum installation temperature
                                                            
                                                            
                                                                -5 °C
                                                            
                                                        Resources
Resources
Documentation
Declaration of Performance
- Declaration of Performance n� : 1000484-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 4
- Declared performance : Fca
Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        - Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
 
- Americas
- Asia
- Europe
- Oceania