FE0-D 3X2.5 2LN

Description

Description

Standards

  • Product
    EN 50575; EN 60529; IEC 60228
  • Test
    EN 60332-1-2; IEC 60754-2; IEC 61034
  • National
    SEV TP 20B/3C-d

Applications

FE0-D NOflamm® is designed for electrical installations requiring a higher level of safety:

  • Installations in public and private buildings
  • Technical rooms and sensitive areas
  • Fixed circuits up to 0.6/1 kV
  • Environments requiring a halogen-free cable
  • Systems installed in humid areas (AD7 protection)

Key advantages

  • Halogen-free, enhanced safety in case of fire
  • Low smoke emission (EN 50399)
  • Flame retardant (IEC 60332-1-2)
  • Water-resistant (AD7), suitable for temporary immersion
  • Wide range of conductor cross-sections available

By choosing FE0-D NOflamm®, you opt for a safe, reliable and durable cable, perfectly suited for professional electrical installations.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Solid class 1
Conductor material
Copper
Conductor shape
Single wired
Halogen free
Yes
Insulation
PE
Outer sheath
HFFR (Halogen Free Flame Retardant)
Sheath colour
Grey
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
2.5 mm²
Approximate weight
127 kg/km
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
8.1 mm

Electrical characteristics

Electrical characteristics

Maximum operating voltage
1000 V
Rated Voltage Uo/U (Um)
0,6/1 kV
Test voltage
3500 V

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2
Maximum operating temperature
70 °C
Minimum installation temperature
-5 °C
Minimum operating temperature
-15 °C
RoHS conform
RoHS 2011/65/EU
Smoke density
EN 50399
Water proof
AD7
Weather resistance
Restricted

Resources

Resources

Documentation

HFFR VS PVC mp4 — 16.0 MB

Declaration of Performance

  • Declaration of Performance n° : 1000272-CHCD
  • Certification Date : 3/1/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 2659
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close