FE0-D-CLN 2X10 RM SW LN
Certifications and labels
FE0-D-CLN 2X10 RM SW LN
FE0-D-CLN NOflamm® is a halogen-free installation cable featuring a light steel armour, specifically designed to effectively protect electrical circuits against rodents and mechanical damage. Water-resistant (AD7), UV-resistant and compliant with NOflamm® requirements, it delivers optimal reliability for technical infrastructures, including outdoor installations or exposed environments.
Read more- Nexans ref. : 10563652
Description
Description
Standards
-
ProductEN 50575; EN 60529; IEC 60228
-
TestEN 60332-1-2; EN 60754-2; IEC 61034
-
NationalSEV TP 20B/3C-d
Applications
FE0-D-CLN NOflamm® is ideal for installations requiring enhanced protection:
- Railway and motorway projects
- Technical rooms and sensitive infrastructures
- Outdoor installations exposed to UV radiation
- Areas with rodent risk
- Fixed circuits up to 0.6/1 kV
- Humid environments (AD7)
Key advantages
- Steel armour: effective protection against rodents
- UV-resistant, ideal for outdoor use
- Water-resistant (AD7), suitable for temporary immersion
- Halogen-free: low smoke emission
- Rated voltage 0.6/1 kV
- CPR class Dca s2,d2,a2
By choosing FE0-D-CLN NOflamm®, you opt for a robust, safe cable perfectly suited for outdoor environments or installations exposed to mechanical risks.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor shape
Round compacted
Conductor material
Copper
Conductor flexibility
Class 2
Insulation
PE
With Green/Yellow core
No
With smaller neutral conductor
No
Inner sheath
HFFR (polyolefin)
Armour type
Steel tapes
Outer sheath
HFFR (Halogen Free Flame Retardant)
Sheath colour
Black
Dimensional characteristics
Dimensional characteristics
Number of cores
2
Conductor cross-section
10 mm²
Approximate weight
555 kg/km
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
17.4 mm
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0,6/1 kV
Maximum operating voltage
1000 V
Test voltage
3500 V
Mechanical characteristics
Mechanical characteristics
Maximum pulling force by laying
- kN
Usage characteristics
Usage characteristics
Minimum Bending Radius during installation
12 (xD)
Minimum Bend Radius - Installed
208.8 mm
Bending factor when installed
12 (xD)
Minimum static operating bending radius
- mm
Minimum installation temperature
-5 °C
Minimum operating temperature
-15 °C
Maximum operating temperature
70 °C
Short-circuit max. conductor temperature
- °C
RoHS conform
RoHS 2011/65/EU
U.V resistance
Yes
Water proof
AD7
Weather resistance
Good
Fire safety characteristics
Fire safety characteristics
Fire load
- MJ/km
Fire retardant
-
Flame retardant
IEC 60332-1-2
Halogen free
Yes
Smoke density
EN 50399
Resources
Resources
Declaration of Performance
- Declaration of Performance n° : 1000759-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 81
- Declared performance : Dca-s2,d2,a2
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania