FE0-D-CLN 4X35 RM SW 3LN
FE0-D-CLN 4X35 RM SW 3LN
Armoured, multi-conductors safety building cables NOflamm
Read more- Nexans ref. : 10545105
Description
Description
Standards
- 
                                            ProductEN 50575; EN 60529; IEC 60228
- 
                                            TestEN 60332-1-2; EN 60754-2; IEC 61034
- 
                                            NationalSEV TP 20B/3C-d
Applications
Halogen-free installation cable with armouring for installation in buildings and equipment rooms. The light steel armouring protects the cable from rodents. This type of cable has been used for years in railway and motorway projects.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Armour type
                                                            
                                                            
                                                                Steel tapes 
                                                            
                                                        
                                                                Conductor flexibility
                                                            
                                                            
                                                                Class 2 
                                                            
                                                        
                                                                Conductor material
                                                            
                                                            
                                                                Copper 
                                                            
                                                        
                                                                Conductor shape
                                                            
                                                            
                                                                Round compacted 
                                                            
                                                        
                                                                Halogen free
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                PE 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                HFFR (Halogen Free Flame Retardant) 
                                                            
                                                        
                                                                Sheath colour
                                                            
                                                            
                                                                Black 
                                                            
                                                        
                                                                With Green/Yellow core
                                                            
                                                            
                                                                No 
                                                            
                                                        
                                                                With smaller neutral conductor
                                                            
                                                            
                                                                No 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Number of cores
                                                            
                                                            
                                                                4 
                                                            
                                                        
                                                                Conductor cross-section
                                                            
                                                            
                                                                35 mm²
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                2207 kg/km
                                                            
                                                        
                                                                Neutral conductor section (when smaller)
                                                            
                                                            
                                                                - mm²
                                                            
                                                        
                                                                Nominal outer diameter
                                                            
                                                            
                                                                31.6 mm
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Maximum operating voltage
                                                            
                                                            
                                                                1000 V
                                                            
                                                        
                                                                Rated Voltage Uo/U (Um)
                                                            
                                                            
                                                                0,6/1 kV 
                                                            
                                                        
                                                                Test voltage
                                                            
                                                            
                                                                3500 V
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Fire load
                                                            
                                                            
                                                                - MJ/km
                                                            
                                                        
                                                                Flame retardant
                                                            
                                                            
                                                                IEC 60332-1-2 
                                                            
                                                        
                                                                Maximum operating temperature
                                                            
                                                            
                                                                70 °C
                                                            
                                                        
                                                                Minimum installation temperature
                                                            
                                                            
                                                                -5 °C
                                                            
                                                        
                                                                Minimum operating temperature
                                                            
                                                            
                                                                -15 °C
                                                            
                                                        
                                                                RoHS conform
                                                            
                                                            
                                                                - 
                                                            
                                                        
                                                                Smoke density
                                                            
                                                            
                                                                EN 50399 
                                                            
                                                        
                                                                U.V resistance
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Water proof
                                                            
                                                            
                                                                AD7 
                                                            
                                                        
                                                                Weather resistance
                                                            
                                                            
                                                                Good 
                                                            
                                                        Resources
Resources
Declaration of Performance
- Declaration of Performance n� : 1000759-CHCD
- Certification Date : 3/1/23
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 81
- Declared performance : Dca-s2,d2,a2
Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        - Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
 
- Americas
- Asia
- Europe
- Oceania