Nexans SIWO-KUL® D30 6.6 / 7.2 kV

Products

SIWO-KUL D30 1x4,0 6,6/7,2 kV GY

Nexans ref. 10560958

  • Packaging: Cut to length (m)
  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 6.95 mm
  • Approximate weight: 74 kg/km
  • Max. DC resistance of the conductor at 20°C: 5.09 Ohm/km
  • Minimum static operating bending radius: 43.62 mm

 

SIWO-KUL D30 1x6,0 6,6/7,2 kV GY

Nexans ref. 10504208

  • Packaging: Cut to length (m)
  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 7.4 mm
  • Approximate weight: 92 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.39 Ohm/km
  • Minimum static operating bending radius: 46.62 mm

 

SIWO-KUL D30 1x10 6,6/7,2 kV GY

Nexans ref. 10548634

  • Packaging: Cut to length (m)
  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: 8.35 mm
  • Approximate weight: 138 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.95 Ohm/km
  • Minimum static operating bending radius: 52.02 mm

 

SIWO-KUL D30 1x35 6,6/7,2 kV GY

Nexans ref. 10510723

  • Packaging: Cut to length (m)
  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 13.2 mm
  • Approximate weight: 398 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.565 Ohm/km
  • Minimum static operating bending radius: 80.82 mm

 

SIWO-KUL D30 1x50 6,6/7,2 kV GY

Nexans ref. 10210808

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 14.9 mm
  • Approximate weight: 542 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.393 Ohm/km
  • Minimum static operating bending radius: 86.7 mm

 

SIWO-KUL D30 1x70 6,6/7,2 kV GY

Nexans ref. 10563000

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 17.0 mm
  • Approximate weight: 715 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.277 Ohm/km
  • Minimum static operating bending radius: 105.72 mm

 

SIWO-KUL D30 1x95 6,6/7,2 kV GY

Nexans ref. 10531426

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 18.7 mm
  • Approximate weight: 923 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.21 Ohm/km
  • Minimum static operating bending radius: 116.52 mm

 

SIWO-KUL D30 1x120 6,6/7,2 kV GY

Nexans ref. 10551374

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 20.7 mm
  • Approximate weight: 1156 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
  • Minimum static operating bending radius: 127.62 mm

 

SIWO-KUL D30 1x150 6,6/7,2 kV GY

Nexans ref. 10559198

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 23.1 mm
  • Approximate weight: 1465 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.132 Ohm/km
  • Minimum static operating bending radius: 116 mm

 

SIWO-KUL D30 1x240 6,6/7,2 kV GY

Nexans ref. 10559210

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 26.8 mm
  • Approximate weight: 2222 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.082 Ohm/km
  • Minimum static operating bending radius: 165.42 mm

 

SIWO-KUL D30 1x300 6,6/7,2 kV GY

Nexans ref. 10562807

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 29.5 mm
  • Approximate weight: 2776 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.065 Ohm/km
  • Minimum static operating bending radius: 187.02 mm

 

Description

Description

Standards

  • Product
    CSA C22.2 N° 210-05; IEC 60228; UL 758
  • Installation
    IEC 60092
  • Test
    IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034

Applications

The SIWO-KUL® D30 cable range has been specifically designed for:

  • Wiring of power cabinets, converters and motor control systems
  • Industrial installations exposed to high thermal stress
  • OEM applications in the wind, marine and railway sectors
  • Connection of windings in rotating machines and Class F and H insulated transformers

Key Advantages

  • High flexibility, ideal for compact installations
  • Excellent thermal resistance (-55°C to +180°C continuous operation)
  • Patented technology ensuring minimal partial discharge levels, even under severe stress
  • Compatible with major impregnation resins
  • Resistant to oils, UV and chemical agents
  • High durability for long service life
  • International approvals and certifications
  • Fire performance properties

Certificate

  • Type approval certificate : LIoyds Register LR21139304TA
  • Type approval certificate : BV Marine & Offshore 09555/D0 BV, file: ACE 01/723/01
  • Certificate of compliance : UL758 AWM Style 3641, file: AVLV2.E45073
  • Certificate of compliance : CSA Standard C22.2 N°210-15, file: LL 36040 AWM

By choosing the SIWO-KUL® range, you opt for a flexible, robust and durable cable designed to guarantee high performance in the most demanding environments.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Sheath colour
Grey

Electrical characteristics

Electrical characteristics

Operating voltage
6.6 kV
Test voltage
20 kV
Breakdown voltage
30 kV
Breakdown field strength (kV/mm)
> 20
Loss factor tan d
< 10-2

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Very flexible
Permissible pulling forces
0.05 kN/mm²

Usage characteristics

Usage characteristics

Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Oil resistance
Good
Ozone resistance
Yes
U.V resistance
Good

Fire safety characteristics

Fire safety characteristics

Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034
Halogen free
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3-24 (cat C)
Fire resistant
IEC 60331

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close