FE0-D-CLN 4X16 RM SW 3LN

Description

Description

Standards

  • Product
    EN 50575; EN 60529; IEC 60228
  • Test
    EN 60332-1-2; EN 60754-2; IEC 61034
  • National
    SEV TP 20B/3C-d

Applications

FE0-D-CLN NOflamm® is ideal for installations requiring enhanced protection:

  • Railway and motorway projects
  • Technical rooms and sensitive infrastructures
  • Outdoor installations exposed to UV radiation
  • Areas with rodent risk
  • Fixed circuits up to 0.6/1 kV
  • Humid environments (AD7)

Key advantages

  • Steel armour: effective protection against rodents
  • UV-resistant, ideal for outdoor use
  • Water-resistant (AD7), suitable for temporary immersion
  • Halogen-free: low smoke emission
  • Rated voltage 0.6/1 kV
  • CPR class Dca s2,d2,a2

By choosing FE0-D-CLN NOflamm®, you opt for a robust, safe cable perfectly suited for outdoor environments or installations exposed to mechanical risks.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor shape
Round compacted
Conductor material
Copper
Conductor flexibility
Class 2
Insulation
PE
With Green/Yellow core
No
With smaller neutral conductor
No
Inner sheath
HFFR (polyolefin)
Armour type
Steel tapes
Outer sheath
HFFR (Halogen Free Flame Retardant)
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Number of cores
4
Conductor cross-section
16 mm²
Approximate weight
1217 kg/km
Neutral conductor section (when smaller)
- mm²
Nominal outer diameter
24.7 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Maximum operating voltage
1000 V
Test voltage
3500 V

Mechanical characteristics

Mechanical characteristics

Maximum pulling force by laying
- kN

Usage characteristics

Usage characteristics

Minimum Bending Radius during installation
12 (xD)
Minimum Bend Radius - Installed
- mm
Bending factor when installed
12 (xD)
Minimum static operating bending radius
- mm
Minimum installation temperature
-5 °C
Minimum operating temperature
-15 °C
Maximum operating temperature
70 °C
Short-circuit max. conductor temperature
- °C
RoHS conform
U.V resistance
Yes
Water proof
AD7
Weather resistance
Good

Fire safety characteristics

Fire safety characteristics

Fire load
- MJ/km
Fire retardant
Flame retardant
IEC 60332-1-2
Halogen free
Yes
Smoke density
EN 50399

Resources

Resources

Declaration of Performance

  • Declaration of Performance n° : 1000759-CHCD
  • Certification Date : 3/1/23
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : 81
  • Declared performance : Dca-s2,d2,a2

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close