GKN+ 3x150 Alrm / 95 Cu 0.6/1 kV

Description

Description

Standards

  • Product
    HD 603; IEC 60228
  • National
    ASE

Applications

This family is designed for aluminium three-core low-voltage cabling in public and industrial networks:

  • Underground low-voltage distribution networks
  • Installation in ducts, trenches, cable trays, and direct burial
  • Electrical substations
  • Infrastructures requiring service continuity and reliability

Key advantages

  • Low-carbon aluminium enabling CO2 reduction of up to 43%
  • 100% recycled outer sheath, significantly reducing environmental impact
  • Lightweight cable for easier handling and pulling
  • Metrium length management for easier pulling
  • HEPR insulation providing excellent mechanical and thermal resistance
  • Full transparency thanks to the PEP Ecopassport
  • Low sheath shrinkage / high abrasion resistance
  • Halogen-free

The GKN+ Alu three-core cable is a sustainable, cost-effective, and optimised solution, ideal for underground LV projects seeking to reduce their carbon footprint while ensuring reliability and performance.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Circular
Conductor flexibility
Stranded class 2
Insulation
HEPR
Core identification
Black, red, white
Material of the outer core / screen
Copper wires
Outer core type
Waveform concentric
Outer sheath
PE
Sheath colour
Black + 2 yellow lines
Halogen free
Yes
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
150 mm²
Conductor diameter
14.4 mm
Diameter over insulation
17.0 mm
Screen section
95 mm²
Diameter over external conductor / metallic screen
42.6 mm
Nominal outer diameter
46.9 mm
Approximate weight
360.5 kg/100m
Neutral conductor section (when smaller)
- mm²
Number of cores
3

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Maximum operating voltage
1 kV
Nominal phase capacitance
0.359 µF / km
Impedance (AC) at max. operating temperature
0.275 Ohm
Phase reactance 50 Hz - trefoil formation
0.07 Ohm/km
Max. DC resistance of the conductor at 20°C
0.206 Ohm/km
I max. @ 60°C-buried, trefoil, joined, earthing 1pt, LF0.627
- A
I max. @ 90°C-buried, trefoil, joined, earthing 1pt, LF0.627
- A
Perm. current rating buried 20°C - trefoil formation
252 A
Perm. current rating in air 30°C - trefoil formation
318 A

Mechanical characteristics

Mechanical characteristics

Maximum pulling force by laying
9 kN

Usage characteristics

Usage characteristics

Bending factor when laying
10 (xD)
Bending factor when installed
8 (xD)
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum installation temperature
-5 °C

Resources

Resources

Declaration of Performance

  • Declaration of Performance n° : 1001340-CHCD
  • Certification Date : 11/27/25
  • AVCP (Assessment and Verification of Constancy of Performance) : System 4
  • Declared performance : Fca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close