Description
Standards
International : EN 45545-2 (HL3); EN 50264-3-1; IEC 60228Description
Applications
For protected durable installation in railway vehicles (locomotives, trains, trolley-busses, etc.), switching stations and control panels. Installation in cable ducts, pipes and tubes.
Current carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2 - HL3.
Design
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Cable marking
Printing white:
Up to 1x10 mm²:
FLAMEX type EN 50264-3-1 1800V (mm²) M 4GKW I NEXANS I WW-YYYY
or
from 1x16 mm² to 1x240 mm²:
FLAMEX EN 50264-3-1 1800V (mm²) M I NEXANS I WW-YYYY
Characteristics
Construction characteristics | |
---|---|
Halogen free | EN 50267-2-1 & EN 60684-2 |
Sheath colour | Black |
Usage characteristics | |
Operating temperature, range | -40 .. 90°C |
Smoke density | IEC 61034-2 & NFF 16101 |
Gases corrosivity | EN 50267-2-2 |
Gases toxicity | EN 50305-9.2 |
Flame retardant | EN 60332-1-2 |
Fire retardant | EN 60332-3-24 & EN 60332-3-25 |
Oil resistance | Yes |
Ozone resistance | Yes |
U.V resistance | Yes |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 1.8/3 (3.6) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 2.7 kV DC |
Testing AC voltage (5 minutes) |
U = 6.5 kV |
Max. operating temperature at conductor
Conductor at normal operation |
≤ 90 °C/250.000 h |
|
≤ 120 °C/20.000 h |
Conductor under short-circuit conditions (tinned) |
≤ 200 °C |
Selling information
Special conditions relating to temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.