FE05-B2 3X2.5 GB LNPE

Description

Description

Standards

  • Product
    EN 50575; EN 60529; IEC 60228
  • Test
    EN 60754-2; EN 61034-2; IEC 60332-1-2
  • National
    SEV TP 20B/3C-d

Applications

FE05-B2 NOflamm® is suitable for installations requiring enhanced fire protection:

  • Electrical installations in buildings and public infrastructures
  • Technical rooms and sensitive areas
  • Tunnels and traffic areas
  • Fixed circuits up to 0.6/1 kV
  • Environments requiring halogen-free, low-smoke cables

 

Key advantages

  • Water-resistant (AD7), suitable for temporary immersion
  • Halogen-free: very low smoke emission
  • Rated voltage 0.6/1 kV
  • CPR class B2ca s1a, d0, a1

By choosing FE05-B2 NOflamm®, you opt for a safe, high-performance and durable cable, ideal for professional installations with the highest safety requirements.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Solid class 1
Conductor material
Copper
Conductor shape
Single wired
Halogen free
Yes
Insulation
PE
Outer sheath
HFFR (Halogen Free Flame Retardant)
Sheath colour
Yellow

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
2.5 mm²
Approximate weight
185 kg/km
Nominal outer diameter
10.1 mm

Electrical characteristics

Electrical characteristics

Maximum operating voltage
1000 V
Rated Voltage Uo/U (Um)
0,6/1 kV
Test voltage
3500 V

Usage characteristics

Usage characteristics

Fire load
1659 MJ/km
Flame retardant
EN 60332-1-2
Maximum operating temperature
90 °C
Minimum operating temperature
-20 °C
Smoke density
EN 50399
U.V resistance
No
Water proof
AD7

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close