Nexans SIWO-KUL® S10 1.1 kV
Nexans SIWO-KUL® S10 1.1 kV
SIWO-KUL® S10 1.1 kV cables are designed with a COPPER braid SCREEN to avoid EMC interference and with a PET braid, PUR varnished
Read moreSIWO-KUL S10 1x16 1,1 kV YE
Nexans ref. 10543304
- Packaging: Cut to length (m)
 - Conductor cross-section: 16 mm²
 - Nominal outer diameter: 11.3 mm
 
SIWO-KUL S10 1x25 1,1 kV YE
Nexans ref. 10510871
- Packaging: Cut to length (m)
 - Conductor cross-section: 25 mm²
 - Nominal outer diameter: 12.85 mm
 
SIWO-KUL S10 1x35 1,1 kV YE
Nexans ref. 10511466
- Packaging: Cut to length (m)
 - Conductor cross-section: 35 mm²
 - Nominal outer diameter: 14.15 mm
 
SIWO-KUL S10 1x50 1,1 kV YE
Nexans ref. 10539524
- Packaging: Cut to length (m)
 - Conductor cross-section: 50 mm²
 - Nominal outer diameter: 16.15 mm
 
SIWO-KUL S10 1x70 1,1 kV YE
Nexans ref. 10510872
- Packaging: Cut to length (m)
 - Conductor cross-section: 70 mm²
 - Nominal outer diameter: 18.35 mm
 
SIWO-KUL S10 1x95 1,1 kV YE
Nexans ref. 10510870
- Packaging: Cut to length (m)
 - Conductor cross-section: 95 mm²
 - Nominal outer diameter: 21.2 mm
 
SIWO-KUL S10 1x120 1,1 kV YE
Nexans ref. 10512514
- Packaging: Cut to length (m)
 - Conductor cross-section: 120 mm²
 - Nominal outer diameter: 22.75 mm
 
SIWO-KUL S10 1x150 1,1 kV YE
Nexans ref. 10526846
- Packaging: Cut to length (m)
 - Conductor cross-section: 150 mm²
 - Nominal outer diameter: 24.55 mm
 
SIWO-KUL S10 1x185 1,1 kV YE
Nexans ref. 10539775
- Packaging: Cut to length (m)
 - Conductor cross-section: 185 mm²
 - Nominal outer diameter: 27.2 mm
 
SIWO-KUL S10 1x240 1,1 kV YE
Nexans ref. 10505413
- Packaging: Cut to length (m)
 - Conductor cross-section: 240 mm²
 - Nominal outer diameter: 29.6 mm
 
SIWO-KUL S10 1x300 1,1 kV YE
Nexans ref. 10543305
- Packaging: Cut to length (m)
 - Conductor cross-section: 300 mm²
 - Nominal outer diameter: 31.65 mm
 
Description
Description
Standards
- 
                                            ProductCSA C22.2 N° 210-05; IEC 60228; IEC 60502-2
 - 
                                            InstallationIEC 60092
 - 
                                            TestIEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034
 
Application
- Connection of rotating machines windings, like motors, alternators, generators.
 - Cabling of static devices, like power converters, motor drives, power cabinets, transformers
 - Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems
 
Construction
- Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
 - High grade silicon rubber insulation
 - Tin platted Cu braid for EMC protection screen
 - Mechanical protection by PUR varnished synthetic fibre braid for enhanced friction resistance
 
Properties
- Operating temperature in continuous mode -55°C to +180°C
 - Resistance to thermal shocks
 
- Type approval certificate : Lloyds Register LR21139304TA
 - Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01
 - Certificate of compliance : CSA Standard C22.2 N°210-15, file : LL 36040 AWM
 
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                            Halogen free
                                                        
                                                        
                                                            Yes 
                                                        
                                                    Electrical characteristics
Electrical characteristics
                                                            Operating voltage
                                                        
                                                        
                                                            1.1 kV
                                                        
                                                    Usage characteristics
Usage characteristics
                                                            Operating temperature, range
                                                        
                                                        
                                                            -55 ... 180 °C
                                                        
                                                    
                                                            Chemical resistance
                                                        
                                                        
                                                            Good 
                                                        
                                                    
                                                            Oil resistance
                                                        
                                                        
                                                            Yes 
                                                        
                                                    
                                                            Flame retardant
                                                        
                                                        
                                                            IEC 60332-1 
                                                        
                                                    
                                                            Fire retardant
                                                        
                                                        
                                                            IEC 60332-3 
                                                        
                                                    
                                                            Fire resistant
                                                        
                                                        
                                                            IEC 60331 
                                                        
                                                    
                                                            Gases corrosivity
                                                        
                                                        
                                                            IEC 60754-1; IEC 60754-2 
                                                        
                                                    
                                                            Smoke density
                                                        
                                                        
                                                            IEC 61034 
                                                        