Low voltage cables type Torsathene
Low voltage cables type Torsathene
LV drilled aerial power cables with aluminium conductors, XLPE insulated.
Read moreTORSATHENE 4 x 150 mm² Al rm 0.6/1 kV
Nexans ref. 10512324
- Packaging: Bag (m)
- Conductor cross-section: 150 mm²
TORSATHENE 4 x 25 mm² Al rm + 1 x 10 mm² Cu re 0.6/1 kV
Nexans ref. 10152876
- Packaging: Bag (m)
- Conductor cross-section: 25 mm²
TORSATHENE 4 x 25 mm² Al rm 0.6/1 kV
Nexans ref. 10152873
- Packaging: Bag (m)
- Conductor cross-section: 25 mm²
TORSATHENE 4 x 50 mm² Al rm + 1 x 10 mm² Cu re, 0.6/1 kV
Nexans ref. 10152877
- Packaging: Bag (m)
- Conductor cross-section: 50 mm²
TORSATHENE 4 x 50 mm² Al rm 0.6/1 kV
Nexans ref. 10152874
- Packaging: Bag (m)
- Conductor cross-section: 50 mm²
TORSATHENE 4 x 95 mm² Al rm + 1 x 10 mm² Cu re, 0.6/1 kV
Nexans ref. 10152878
- Packaging: Bag (m)
- Conductor cross-section: 95 mm²
TORSATHENE 4 x 95 mm² Al rm 0.6/1 kV
Nexans ref. 10152875
- Packaging: Bag (m)
- Conductor cross-section: 95 mm²
TORSATHENE 4x150 mm² Al rm + 1x10 mm² Cu re, 0.6/1 kV
Nexans ref. 10217445
- Packaging: Bag (m)
- Conductor cross-section: 150 mm²
Description
Description
Standards
-
ProductHD 603
-
NationalASE
Applications
Applications
- Wooded areas (tree felling is partly unnecessary)
- For sections endangered by falling trees and snow and wind loads (fallen lines can remain in service)
- To reinforce existing lines
Construction
- Wooded areas (tree felling is partly unnecessary)
- For sections endangered by falling trees and snow and wind loads (fallen lines can remain in service)
- To reinforce existing lines
Properties
- With the same cross-section, the voltage drops are significantly lower (lower inductivity)
- Completely insulated network
- Protection of installation personnel
- Live connection possible
- Significantly lower maintenance costs
- Similar or lower construction costs
Torsathene value
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor material
Aluminum
Conductor shape
Circular
Conductor flexibility
Stranded class 2
Insulation
XLPE (chemical)
Colour
Black
Core identification
0 to 3 rills
With Green/Yellow core
No
With smaller neutral conductor
No
Dimensional characteristics
Dimensional characteristics
Neutral conductor section (when smaller)
- mm²
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
0,6/1 kV
Maximum operating voltage
1000 V
Test voltage
4000 V
Usage characteristics
Usage characteristics
Field of application
Aerial
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C