H07RN-F TITANEX® PREMIUM

Products

TITANEX PREMIUM 4X1X240

Nexans ref. 10559644

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 240 mm²
  • Dynamic bending factor: 10 (xD)

 

TITANEX PREMIUM 4X1X300

Nexans ref. 10566716

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 300 mm²
  • Dynamic bending factor: 10 (xD)

 

TITANEX PREMIUM 4x1x150

Nexans ref. 10564517

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 150 mm²
  • Dynamic bending factor: 10 (xD)

 

TITANEX PREMIUM 4x1x185

Nexans ref. 10559643

  • Packaging: Cut to length (m)
  • Number of cores: 4
  • Conductor cross-section: 185 mm²
  • Dynamic bending factor: 10 (xD)

 

TITANEX® PREMIUM 1x150 GL

Nexans ref. 10211733 - Country ref. 01272295

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 150 mm²
  • Dynamic bending factor: 8 (xD)

 

TITANEX® PREMIUM 1x185 GL

Nexans ref. 10211824 - Country ref. 01272296

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 185 mm²
  • Dynamic bending factor: 8 (xD)

 

TITANEX® PREMIUM 1x240 GL

Nexans ref. 10211825 - Country ref. 01272297

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 240 mm²
  • Dynamic bending factor: 8 (xD)

 

TITANEX® PREMIUM 1x300 GL

Nexans ref. 10211826 - Country ref. 01272298

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 300 mm²
  • Dynamic bending factor: 8 (xD)

 

TITANEX® PREMIUM 1x400 GL

Nexans ref. 10225406 - Country ref. 01272299

  • Packaging: Cut to length (m)
  • Number of cores: 1
  • Conductor cross-section: 400 mm²
  • Dynamic bending factor: 8 (xD)

 

Description

Description

Standards

  • Product
    IEC 60228
  • Test
    IEC 60332-1; IEC 60754-1; IEC 60754-2

Use

TITANEX® PREMIUM is a new H07RN-F cable with a wide  variety of properties. It is zero halogen and recommended for use in the case of fire risk. It also includes the properties of H07RN8-F cables for resistance to submersion (AD8), H07BN4-F cables for operating temperature (90°C), and H07BB-F cables for use in extreme cold conditions (down to -50°C).

 

Classification for use

  • CPR Class Eca
  • Use up to 1000V for fixed installations or power supply of motors
  • Resistance to submersion: AD8
  • Presence of corrosive or polluting substances: AF3
  • Resistance to impacts: AG2
  • Zero halogen (LSOH)
  • Flame retardant (NF C 32070 C2; IEC 60332-1)
  • Frequent bending: good
  • Oil resistance: good
  • Low temperature use limit: -50°C (static), -40°C (dynamic)

 

 

Recommendations for use

The insulation and sheathing combinations result in excellent flexibility and good robustness, therefore the product is recommended for use in power cables for port cranes, mobile machines on public building sites, professional portable tools, refrigerating installations, long-term heavy-duty applications in port areas, on ships, offshore platforms…

Further applications include all public-facing facilities as well as buildings containing electronic equipment, central control rooms, airports, railway stations, road tunnels, lighting equipment, etc.

Installation

This cable is designed for open air operation. In the event it should be buried, it should be mechanically protected in a duct or trough.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper class 5
Insulation
Cross-linked synthetic elastomer type EI 4 waterproof, EI 6, EI 7, EI 8
Outer sheath
Cross-linked synthetic elastomer type EM2 waterproof, EM6, EM7, EM8
Sheath colour
Black
Conductor flexibility
Class 5
Conductor shape
Circular
Halogen free
Yes
With Green/Yellow core
No

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V

Usage characteristics

Usage characteristics

Flame retardant
NFC 32070 C2, IEC 60332-1-2
Max. conductor temperature in service
90 °C
Minimum operating temperature
-50 °C
Oil resistance
Good
RoHS compliant
Yes
Short-circuit max. conductor temperature
250 °C
U.V resistance
Yes
Water proof
AD8

Resources

Resources

Documentation

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close