SIWO-KUL B10 1x25 3,3/4,2kV RD

Description

Description

Standards

  • International
    EN 45545 - HL3; IEC 60092; IEC 60228; IEC 60331; IEC 60332-1; IEC 60332-3-22; IEC 60332-3-24; IEC 60754-1; IEC 60754-2; IEC 61034
  • National
    CSA C22.2 N° 210-05; UL 758

Application

  • Connection of rotating machines windings, like motors, alternators, generators.
  • Cabling of static devices, like power converters, motor drives, power cabinets, transformers
  • Adapted for wind turbines, marine and offshore, rollingstock, photovoltaic, energy storage systems

Construction

  • Flexible tin-plated copper conductor class 5 as per IEC 60228, other class in option
  • High grade silicon rubber insulation
  • Mechanical protection by PUR varnished synthetic fibre braid for enhanced friction resistance

Properties

  • Operating temperature in continuous mode -55°C to +180°C
  • Resistance to thermal shocks, UV and oils
  • Enhanced friction resistance with the PUR varnished range
  • Compatibility to VPI impregnation resins

 

  • Type approval certificate : Lloyds Register LR21139304TA
  • Type approval certificate : BV Marine & Offshore 09555/D0 BV, file : ACE 01/723/01
  • Certificate of compliance : UL758 AWM Style 3641, file : AVLV2.E45073
  • Certificate of compliance : CSA Standard C22.2 N°210-15, file : LL 36040 AWM

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tinned copper
Conductor flexibility
Flexible class 5
Insulation
Special Silicone
Halogen free
Yes
Outer sheath
Synthetic yarn braiding
Construction type
180 x 0.40
Dielectric
Yes

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
25 mm²
Nominal outer diameter
12.0 mm
Approximate weight
302 kg/km
Conductor diameter
7.1 mm

Electrical characteristics

Electrical characteristics

Operating voltage
3.3 kV
Test voltage
10 kV
Max. DC resistance of the conductor at 20°C
0.795 Ohm/km
Breakdown voltage
20 kV
Breakdown field strength (kV/mm)
> 20
Dielectric constant relative value (indicative)
3.50
Loss factor tan d
< 10-2

Mechanical characteristics

Mechanical characteristics

Minimum Tensile Strength
8 MPa
Cable flexibility
Flexible
Elongation at break of insulation (%)
> 250

Usage characteristics

Usage characteristics

Minimum static operating bending radius
60 mm
Operating temperature, range
-55 ... 180 °C
Chemical resistance
Good
Maximum operating temperature
180 °C
Minimum operating temperature
-55 °C
Oil resistance
Yes
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Fire resistant
IEC 60331
Gases corrosivity
IEC 60754-1; IEC 60754-2
Smoke density
IEC 61034
Packaging
Cut to length
Ozone resistance
Yes
U.V resistance
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close