Application

For general use in safety devices for the transmission of alternating currents up 90 kHz.

 

Installation

Direct buried, duct and trench laying along railway lines.

 

Temperatures

-10°C ... +60°C  for installation
-40°C ... +60°C  for operation

 

Key features

Compact cable design
Cable sizes from 1 to 40 quads
Three different classes of EMC protection at 16,7 (50) Hz

 

Special versions on request

Manufacturing acc. national and international standards
Customizing of the cable design (z.B. "2B0.3 mm")
Customizing of the EMC protection

 

Ordering example

AJ-2Y(L)2YDB2Y 10x4x1.4 S (H45) rk 504

 

Erklärung der Buchstaben des Buchstabenkurzzeichens:

A-    Aussenkabel (ohne Induktionsschutz)
AJ-     Aussenkabel (mit Induktionsschutz)
B     Bewehrung aus Stahlband
D     konzentrischer Schirm aus Kupferdrähten
2Y     Aufbauelement aus Polyethylen (Isolierhülle, Kabelmantel, äussere Schutzhülle)
2YV    wie vor, jedoch mit erhöhter Wanddicke (verstärkte Ausführung, z.B. des Kabelmantels)
(L)2Y   Schichtenmantel
(L)2YV   Schichtenmantel mit erhöhter Wanddicke


 TOP
Caractéristiques câble de signalisation H45

Cable Design

 

 

Conductor

Copper, round, massive and annealed

 

 

Insulation

Polyethylen

 

 

Element type

star quad

 

 

Cable core lay-up

Layer stranding

 

 

Core wrapping

Several layers of non-hygroscopic plastic tapes

 

 

sheathing

LAP sheathing (reinforced for all non-armoured types)

 

 

screening (AJ- type)

helically applied copper wires

 

 

Armouring (all except A- ...2YV)

One or two layers (AJ-) of helically applied galvanized steel tapes

 

 

Outer sheath

PE sheathing, black

 

 

Dimensions

unit

0.9 mm

1.4 mm

 

 

Conductor diameter

mm

0.9

1.4

 

 

Cable size

quads

from 1 to 40

 

 

Standard delivery length

m

500 / 1000

 

 

Electrical characteristics

unit

0.9 mm

1.4 mm

 

 

Loop resistance

max. 

Ohm/km

56.6

23.4

 

 

Mutual capacitance

nominal 

nF/km

45

 

 

Insulation resistance

min. 

GOhm x km

10

 

 

Capacitance unbalance at 800 Hz 

 

 

 

 

- within quads and between adjacent quads

 

 

 

 

max. individual value, 100 % 

pF/500 m

500

 

 

max. individual value, 50 % 

pF/500 m

150

-

 

 

- between all non-adjacent quads,                max.

pF/500 m

150

 

 

- to ground,                                                max.

pF/500 m

1300

 

 

Dielectric strength, AC, 1 min

 

 

 

 

core/core  and  core/screen 

V

2500

 

 

Transmission characteristics at 90 kHz

unit

0.9 mm

1.4 mm

 

 

Attenuation                                                max.

dB/km

3.3

 23.4

 

 

Far-end crosstalk for 1000 m             min, 100 %

dB

58

33

 

 

 

min., 80 % 

dB

62

33

 

 

EMC properties

unit

 

 

 

Reduction factor at 16,7 Hz

min. 

 

 

 

 

Typical value between  70 ... 100 V/km 

-

0.15 ... 0.55 depending of cable type

 

 

Reduction factor at 50 Hz

min. 

 

 

 

 

Typical value between  200 ... 300 V/km 

-

0.09 ... 0.29 depending of cable type

 

 

Mechanical properties

unit

 

 

 

Min. bending radius for ...

 

 

 

 

 

repeated bending (all types) 

-

20 x D

 

 

final shaping with armouring 

-

15 x D

 

 

final shaping without armouring 

-

10 x D

 

 


 TOP