Deutsch français Login Get Registered Catalog Browser Contact Us
Cables, accessories for LV,MV,HV Power and FTTx, copper Telecom networks, cabling Building and Industry - www.nexans.ch – Nexans

About Nexans

Products and Solutions

Customer Service

Work at Nexans

News and Press

Go

ZPFU-SH Railway signalling cables

Send link to this page print Your Nexans contact on this page
ZPFU-SH Railway signalling cables Signalling circuits in railway networks
Standards
National  NF C 32-070/C1; SNCF CT 445
Description

Applications

  • Signalling cicuits in railway networks

 

Key-points

  • Halogen free
  • Flame retardant
  • Armoured 

 

Design

 

  • Conductor: Copper wire, 1.13 mm nominal diameter (1 mm² Cross section)
  • Insulation: solid polyethylene
  • Twinning: two conductors are twisted to form a pair
  • Stranding: pairs are helically stranded to get the cable core
  • Core wrapping: plastic tape(s) with overlapping
  • Inner sheath: HFFRLS compound
  • Mechanical protection: two helically applied steel tapes
  • Outer sheath: HFFRLS compound

 

Other versions on request

  • ZPFU: PE/PVC sheaths and NF C 32-070 Category C2 compliant

 TOP
Characteristics
Construction characteristics
Outer sheath LSHFFR compound  
Protection Plastic tape with overlapping  
Electromagnetic shield Two steel tapes helically applied  
Halogen free PE  
Lay Up Helically stranded pairs  
Conductor material Aluminium / Polyester tape  
Inner sheath LSHFFR compound  
Dimensional characteristics
Conductor cross-section 1mm²  
Conductor diameter 1.1mm  
Electrical characteristics
Capacitance unbalance max. 400pF/500m  
Max. DC resistance of the conductor at 20°C 18.1Ohm/km  
Dielectric strength core to core DC, min. 4.5kV  
Ohmical resistance of the insulation 5000MOhm.km  
Mutual capacitance 55nF/km  
Usage characteristics
Flame retardant Yes  

 TOP
Results   8/8
Select all Items Nexans ref. Name nb pairs Insulation
**17EPFU0014***A* Signalling cable ZPFU-SH 14 pars 14 Solid polyethylene
**17EPFU0021***A* Signalling cable ZPFU-SH 21 pars 21 Solid polyethylene
**17EPFU0001***A* Signalling cable ZPFU-SH 1 par 1 Solid polyethylene
**17EPFU0002***A* Signalling cable ZPFU-SH 2 pars 2 Solid polyethylene
**17EPFU0028***A* Signalling cable ZPFU-SH 28 pars 28 Solid polyethylene
**17EPFU0004***A* Signalling cable ZPFU-SH 4 pars 4 Solid polyethylene
**17EPFU0056***A* Signalling cable ZPFU-SH 56 pars 56 Solid polyethylene
**17EPFU0007***A* Signalling cable ZPFU-SH 7 pars 7 Solid polyethylene
Add to favorites

 TOP
Electrical Characteristics at 20°C

Parameter

Unit

Value

1. DC conductor resistance
    Maximum


Ω/km


18.1

2. Insulation resistance
    Minimum value after 3 min, 500 VDC


MΩ/km


5000

3. Mutual capacitance
    AC 1000Hz, maximum


nF/km


55

4. Capacitance unbalance
    Maximum


pF/500 m


400

5. Dielectric strength
    Between conductors, 3 min DC voltage


V


4500

6. Attenuation
    20 kHz < f < 45 kHz, maximum
    45 kHz < f < 80 kHz, maximum


dB/km
dB/km


2.5
3.0

7. Characteristic impedance
    20 kHz < f < 45 kHz, nominal
    45 kHz < f < 80 kHz, nominal


Ω
Ω


120±10
115±10


 TOP