BALISE Railway cables

Send link to this page print Your Nexans contact on this page
BALISE Railway cables Balise cable for ETCS railway networks
Standards
International  IEC 60754-1; IEC 60754-2
Description

Preferential use
 

  • cable for ETCS balise railway networks
  • Siemens CH + DE Approved

 

 

Key-points

  • for connecting ETCS balise
  • SBB I-AT-FS  approved - 3001.52.2000 
  • Siemens approved -  MKA 815.1 
  • Low reduction factor
  • Rodent protection
  • radial water protection (moisture barrier)

 

Cable construction

  • Conductor: Bare Copper wire 
  • Insulation: polyethylene
  • Stranding
  • Screen: Aluminium/polyethylene coated tape longitudinally applied and overlapped
  • Intermediate sheath: polyethylene
  • Armour: Two galvanized steel tapes
  • Outer sheath: Black polyethylene

 

Remarks:
On request with HFFR sheath


 TOP
Characteristics
Construction characteristics
Armour type Galvanized steel tapes  
Outer sheath PE  
Screen Aluminium coated tape  
Halogen free PE  
Sheath colour Black  
Insulation Solid polyethylene  
Conductor material Bare copper  
Inner sheath Polyethylene  
Dimensional characteristics
Precision of diameter +/- 0.7 mm  
Electrical characteristics
Dielectric strength core to screen DC, min. 2.5kV  
Dielectric strength core to core DC, min. 2.5kV  
Usage characteristics
Weather resistance Good  
Water proof Radial  
Minimum operating temperature -30°C  
Maximum operating temperature 70°C  
Minimum installation temperature -5°C  

 TOP
Results   6/6 Show full list
Select all Items Nexans ref. Name Conductor diam. (mm) Nom. outer diam. (mm) Approx. weight (kg/km)
Make to order product 10205675 RW-BA-SIEMENS PE-ALT-CLT 1X2/1,60 SW 1.6 17.5 285
10178681 RW-BA-SIEMENS PE-ALT-CLT 1X4/1,53 SW 1.53 17.1 300
Add to favorites

 TOP
CABLE BALISE Transmission Characteristics

Parameter

Frequency

Unit

Value

Mutual capacity

800 Hz

nF/km

42.3 +/- 15%

Coppling K1

800 Hz

pF/km

max. 240

Coppling to earth ea1, ea2

800 Hz

pF/km

max. 640

Impedance

0.56 MHz

Ohm

120 +/- 10%

 

0.80 MHz

Ohm

120 +/- 10%

 

1.8 MHz

Ohm

120 +/- 5%

Attenuation

8.82 kHz

dB/100m

0.08

 

0.56 MHz

dB/100m

0.40

 

0.80 MHz

dB/100m

0.50

 

1.8 MHz

dB/100m

0.80


 TOP
Selling delivery information
Standard delivery length : 2'000m Max. delivery length : 3'000m